The number one site for CADmep™ ESTmep™ and CAMduct™ users... | |
including additional topics and discussions covering AutoCAD®, Navisworks®, Revit®, GTP Stratus, and much more |
|
![]() |
Started in 2003, XtraCAD.com was set up as a platform to aid users of the newly evolving range of 3D parametric modelling software utilities being developed by Micro Application Packages (MAP) from Blackpool, England. Throughout the continual development of these applications, including the acquisition of MAP by Autodesk® in 2011 and subsequent rebranding, we have remained the first port of call for many users of all levels seeking assistance. We are proud that Autodesk 'fully understand the importance of XtraCAD for the CADmep and Fabrication community' and acknowledge that we 'do a great service by maintaining this community and understand it is important for users'. Join us now and become a part of the future of Building Services Coordination & BIM. |
|
EU Law: By signing in to this site I agree that XtraCAD.com may set cookies on my browser.
Today at 06:24:57 PM by cnash | Views: 4 | Comments: 0
So, starting in version 2019 it seems like doublewall doesn't work correctly. For example in 2018 and before you apply a 2" insulation doublewall on a 24x24 piece of rectangular duct and us... Today at 05:06:10 PM by Axl | Views: 11 | Comments: 0
I created a tank model that will actually not used in my office, but I'm so proud of it, that I decided to post it here, I tested it in CAD and Revit and it is working fine, Let me know if ... Today at 01:57:34 AM by dfiorini | Views: 32 | Comments: 0
I have catalogue items with CAD blocks attached to show strut code clearances etc… When plotting an ISO view I have the code clearance shut off inside the independent view port. But when I... Yesterday at 09:14:46 PM by piper1 | Views: 38 | Comments: 2
Hello all, Is there a way to find the aggregate length of all the segments of a designline? Thanks! Jan 15, 2021, 08:54:58 PM by jaysomlam | Views: 2042 | Comments: 4
I would like to know which command that I can call to show the piece number tags of the duct items on a drawing in CADmep. I would like to write a program to operate on the duct item. A part of the ... Pages: [1]
|
Anyone figure out a fix for Double Wall in 2019-2021? by cnash
[Today at 06:24:57 PM] Re: Designline length by dopefish [Today at 05:50:15 PM] Re: Edit Fabrication database outside of CADmep by RandallFlagg [Today at 05:33:02 PM] Revit-Fabrication Parts-using CID1110 by Axl [Today at 05:06:10 PM] Re: How to Call a Script to Process an Item Using Fabrication API? by jaysomlam [Today at 04:57:58 PM]
From here you may access additional areas of the site..
|